Growth rate-corrected (GR) dose-response metrics across a panel of 71 breast cancer cell lines treated with a library of small molecule and antibody perturbagens. Dataset 1 of 4: Relative cell counts and normalized growth rate inhibition values across technical replicates. - Dataset (ID:20268)

Filter results: >>>>
Cell Clinical Subtype Transcriptional Subtype Small Molecule Antibody Perturbagen Target Perturbagen Class Perturbagen Concentration Perturbagen Conc Unit Biological Replicate ID Relative Cell Count Normalized Growth Rate Inhibition Value Nominal Division Rate
MDA-MB-361
HER2amp
Luminal
JNK-IN-5A
JNK
JNK
0.00853
uM
10643.144
0.9741 0.9282 0.7178
MDA-MB-361
HER2amp
Luminal
JNK-IN-5A
JNK
JNK
0.0427
uM
10643.144
0.9659 0.9057 0.7178
MDA-MB-361
HER2amp
Luminal
JNK-IN-5A
JNK
JNK
0.213
uM
10643.144
0.9941 0.9835 0.7178
MDA-MB-361
HER2amp
Luminal
JNK-IN-5A
JNK
JNK
1.07
uM
10643.144
0.8813 0.6772 0.7178
MDA-MB-361
HER2amp
Luminal
JNK-IN-5A
JNK
JNK
5.33
uM
10643.144
0.5265 -0.1818 0.7178
MDA-MB-361
HER2amp
Luminal
JNK-IN-5A
JNK
JNK
26.7
uM
10643.144
0.6380 0.0693 0.7178
MDA-MB-361
HER2amp
Luminal
JNK-IN-5A
JNK
JNK
133
uM
10643.144
0.5227 -0.1900 0.7178
MDA-MB-361
HER2amp
Luminal
JNK-IN-5A
JNK
JNK
0.000341
uM
10999.144
1.0718 1.2119 0.6880
MDA-MB-361
HER2amp
Luminal
JNK-IN-5A
JNK
JNK
0.00171
uM
10999.144
1.0491 1.1444 0.6880
MDA-MB-361
HER2amp
Luminal
JNK-IN-5A
JNK
JNK
0.00853
uM
10999.144
1.0572 1.1685 0.6880
MDA-MB-361
HER2amp
Luminal
JNK-IN-5A
JNK
JNK
0.0427
uM
10999.144
1.0300 1.0878 0.6880
MDA-MB-361
HER2amp
Luminal
JNK-IN-5A
JNK
JNK
0.213
uM
10999.144
0.9894 0.9693 0.6880
MDA-MB-361
HER2amp
Luminal
JNK-IN-5A
JNK
JNK
1.07
uM
10999.144
1.0572 1.1685 0.6880
MDA-MB-361
HER2amp
Luminal
JNK-IN-5A
JNK
JNK
5.33
uM
10999.144
0.5228 -0.2207 0.6880
MDA-MB-361
HER2amp
Luminal
JNK-IN-5A
JNK
JNK
26.7
uM
10999.144
1.0872 1.2585 0.6880
MDA-MB-361
HER2amp
Luminal
JNK-IN-5A
JNK
JNK
133
uM
10999.144
1.0936 1.2778 0.6880
MDA-MB-361
HER2amp
Luminal
JNK-IN-5A
JNK
JNK
0.000512
uM
12379.168
1.0557 1.2459 0.4672
MDA-MB-361
HER2amp
Luminal
JNK-IN-5A
JNK
JNK
0.00256
uM
12379.168
1.1013 1.4589 0.4672
MDA-MB-361
HER2amp
Luminal
JNK-IN-5A
JNK
JNK
0.0128
uM
12379.168
1.0695 1.3095 0.4672
MDA-MB-361
HER2amp
Luminal
JNK-IN-5A
JNK
JNK
0.064
uM
12379.168
1.0073 1.0316 0.4672
MDA-MB-361
HER2amp
Luminal
JNK-IN-5A
JNK
JNK
0.32
uM
12379.168
1.0507 1.2234 0.4672
MDA-MB-361
HER2amp
Luminal
JNK-IN-5A
JNK
JNK
1.6
uM
12379.168
1.0634 1.2815 0.4672
MDA-MB-361
HER2amp
Luminal
JNK-IN-5A
JNK
JNK
8
uM
12379.168
1.0077 1.0329 0.4672
MDA-MB-361
HER2amp
Luminal
JNK-IN-5A
JNK
JNK
40
uM
12379.168
1.0617 1.2736 0.4672
MDA-MB-361
HER2amp
Luminal
JNK-IN-5A
JNK
JNK
200
uM
12379.168