Evaluation of the sensitivity of two triple-negative breast cancer cell lines (HCC1806, HCC70) to a collection of dual mTOR and PI3K-like kinase (PIKK) inhibitors. Dataset 1 of 2: GR values. - Dataset (ID:20366)

    
  Fixation Time Point: 
    Fixation Time Point: 72 hours
  Imaging Control Sample: 
    Imaging Control Sample: FALSE
  Imaging: 
    Settings_Group: 
      Imaging_Microscope_Type: 3D 
      Imaging_Detector_Type: sCMOS 
      Imaging_Detector_Bit_Depth: 16 
      Imaging_Detector_Binning: 2x2 
      Imaging_Light_Source: Xenon 
      Imaging_Lens_Immersion_Type: air 
      Imaging_Lens_Numerical_Aperture: 0.75 
      Imaging_Lens_Optical_Correction:  
      Imaging_Magnification: 10 
      Imaging_Pixelsize: 1.32 um 
      Imaging_Z_Dimension: 1 
      Imaging_Z_Stepsize: n/a
    Design_Group: 
      Imaging_Plate_Format: 384 Well 
      Imaging_Replication_Type: isogenic 
      Imaging_Replication_Count: 4 
      Imaging_Type: fixed 
      Imaging_Fixative: 4% formaldehyde 
      Imaging_Permeabilization_Agent: n/a 
      Imaging_Blocking_Agent: n/a
    Incubation_Group: 
      Imaging_Incubator: FALSE 
      Imaging_Incubator_Temp: n/a 
      Imaging_Incubator_CO2: n/a 
      Imaging_Incubator_O2: n/a 
      Imaging_Incubator_Humidity: n/a
    Time_Group: 
      Imaging_Live: FALSE 
      Imaging_Total_Time: n/a 
      Imaging_Time_Interval: n/a 
      Imaging_Total_Number: 1
    Imaging_Acquisition_Group_Rounds: 2 
    Acquisition_Groups: 
        Imaging_Acquisition_Group: 1 
        Imaging_Channel_Count: 2 
        Imaging_Channel_Method: sequential 
        Imaging_Channels: 
            Imaging_Channel: 1 
            Imaging_Method: Fluorescence 
            Imaging_Excitation_Wavelength: Xenon 
            Imaging_Excitation_Power: n/a 
            Imaging_Excitation_Filter: 360 400 
            Imaging_Dichroic_Filter: n/a 
            Imaging_Emission_Filter: 410 480 
            Imaging_Exposure_Time: variable 
            Imaging_Detector_Gain: n/a 
            Imaging_Marker_Intrinsic: FALSE 
            Imaging_Marker_Antibodies: FALSE 
            Imaging_Marker_Compounds: TRUE 
            Imaging_Marker_Sample_Specification: Hoechst
            Imaging_Channel: 2 
            Imaging_Method: Fluorescence 
            Imaging_Excitation_Wavelength: Xenon 
            Imaging_Excitation_Power: n/a 
            Imaging_Excitation_Filter: 620 640 
            Imaging_Dichroic_Filter: n/a 
            Imaging_Emission_Filter: 650 700 
            Imaging_Exposure_Time: variable 
            Imaging_Detector_Gain: n/a 
            Imaging_Marker_Intrinsic: FALSE 
            Imaging_Marker_Antibodies: FALSE 
            Imaging_Marker_Compounds: TRUE 
            Imaging_Marker_Sample_Specification: LDR