MCF 10A-H2B-mCherry - Cell Line (ID:51124)
HMS LINCS ID: | 51124 |
Name: | MCF 10A-H2B-mCherry |
Alternative Names: | |
LINCS ID: | |
Alternative ID: | CLO_0007599 |
Parent Cell Line: | HMSL50583-7: MCF 10A |
Reference Source: | Mario Niepel (Harvard Medical School) |
Organism: | Homo sapiens |
Organ: | breast |
Tissue: | |
Cell Type: | epithelial |
Details of Cell Type: | |
Donor Sex: | female |
Donor Age: | |
Donor Ethnicity: | |
Donor Health Status: | |
Disease: | fibrocystic disease |
Details of Disease: | non-tumorigenic |
Production Details: | Modification type: retroviral transformation with an H2B-mCherry expression cassette that comprised AAVS1 homology arms, the hPGK promotor, and SV40 polyA terminator and integration into the AAVS1 safe harbor genomic locus using CRISPR/Cas9; followed by clonal selection based on transgene expression level. Citations: H2B-mCherry expression cassette: gift of Robert Benezra (Memorial Sloan Kettering Cancer Center), Addgene plasmid #20972; SV40 polyA terminator: gift from Rudolf Jaenisch (Whitehead Institute for Biomedical Research), Addgene plasmid # 22072. |
Genetic Modification(s): | H2B-mCherry integration at AAVS1 safe harbor locus |
Known Mutations: | |
Citation Information for Mutations: | |
Verification Reference Profile: | |
Growth Properties: | adherent |
Recommended Culture Conditions: | |
Relevant Citations: | PMID 27135972 |
Usage Note: | |
Comments: | |
Date Publicly Available: | 2016-08-24 |
Most Recent Update: | 2016-08-24 |
Datasets:
HMS Dataset ID | Dataset Title | HMS Dataset Type |
---|---|---|
20278 | LINCS MCF 10A Common Project: Fixed-time-point sensitivity measures of the MCF 10A breast cell line to 8 small molecule perturbagens. Dataset 1 of 9: Cell count and normalized growth rate inhibition values for biological replicate 1 | Microscopy/Imaging |
20279 | LINCS MCF 10A Common Project: Fixed-time-point sensitivity measures of the MCF 10A breast cell line to 8 small molecule perturbagens. Dataset 2 of 9: Cell count and normalized growth rate inhibition values for biological replicate 2 | Microscopy/Imaging |
20280 | LINCS MCF 10A Common Project: Fixed-time-point sensitivity measures of the MCF 10A breast cell line to 8 small molecule perturbagens. Dataset 3 of 9: Cell count and normalized growth rate inhibition values for biological replicate 3 | Microscopy/Imaging |
20281 | LINCS MCF 10A Common Project: Fixed-time-point sensitivity measures of the MCF 10A breast cell line to 8 small molecule perturbagens. Dataset 4 of 9: Mean cell count and mean normalized growth rate inhibition values for biological replicate 1 | Microscopy/Imaging |
20282 | LINCS MCF 10A Common Project: Fixed-time-point sensitivity measures of the MCF 10A breast cell line to 8 small molecule perturbagens. Dataset 5 of 9: Mean cell count and mean normalized growth rate inhibition values for biological replicate 2 | Microscopy/Imaging |
20283 | LINCS MCF 10A Common Project: Fixed-time-point sensitivity measures of the MCF 10A breast cell line to 8 small molecule perturbagens. Dataset 6 of 9: Mean cell count and mean normalized growth rate inhibition values for biological replicate 3 | Microscopy/Imaging |
20284 | LINCS MCF 10A Common Project: Fixed-time-point sensitivity measures of the MCF 10A breast cell line to 8 small molecule perturbagens. Dataset 7 of 9: Calculated dose-response metrics for biological replicate 1 | Analysis |
20285 | LINCS MCF 10A Common Project: Fixed-time-point sensitivity measures of the MCF 10A breast cell line to 8 small molecule perturbagens. Dataset 8 of 9: Calculated dose-response metrics for biological replicate 2 | Analysis |
20286 | LINCS MCF 10A Common Project: Fixed-time-point sensitivity measures of the MCF 10A breast cell line to 8 small molecule perturbagens. Dataset 9 of 9: Calculated dose-response metrics for biological replicate 3 | Analysis |
20309 | LINCS MCF 10A Common Project: Rolling-time-point sensitivity measures of the MCF 10A breast cell line to 8 small molecule perturbagens. Dataset 1 of 15: End-point cell counts and normalized growth rate inhibition values for all technical replicates of biological replicate 1. | Microscopy/Imaging |
20310 | LINCS MCF 10A Common Project: Rolling-time-point sensitivity measures of the MCF 10A breast cell line to 8 small molecule perturbagens. Dataset 2 of 15: End-point cell counts and normalized growth rate inhibition values for all technical replicates of biological replicate 2. | Microscopy/Imaging |
20311 | LINCS MCF 10A Common Project: Rolling-time-point sensitivity measures of the MCF 10A breast cell line to 8 small molecule perturbagens. Dataset 3 of 15: End-point cell counts and normalized growth rate inhibition values for all technical replicates of biological replicate 3. | Microscopy/Imaging |
20312 | LINCS MCF 10A Common Project: Rolling-time-point sensitivity measures of the MCF 10A breast cell line to 8 small molecule perturbagens. Dataset 4 of 15: End-point mean cell counts and mean normalized growth rate inhibition values for biological replicate 1. | Microscopy/Imaging |
20313 | LINCS MCF 10A Common Project: Rolling-time-point sensitivity measures of the MCF 10A breast cell line to 8 small molecule perturbagens. Dataset 5 of 15: End-point mean cell counts and mean normalized growth rate inhibition values for biological replicate 2. | Microscopy/Imaging |
20314 | LINCS MCF 10A Common Project: Rolling-time-point sensitivity measures of the MCF 10A breast cell line to 8 small molecule perturbagens. Dataset 6 of 15: End-point mean cell counts and mean normalized growth rate inhibition values for biological replicate 3. | Microscopy/Imaging |
20315 | LINCS MCF 10A Common Project: Rolling-time-point sensitivity measures of the MCF 10A breast cell line to 8 small molecule perturbagens. Dataset 7 of 15: End-point dose-response metrics for biological replicate 1. | Analysis |
20316 | LINCS MCF 10A Common Project: Rolling-time-point sensitivity measures of the MCF 10A breast cell line to 8 small molecule perturbagens. Dataset 8 of 15: End-point dose-response metrics for biological replicate 2. | Analysis |
20317 | LINCS MCF 10A Common Project: Rolling-time-point sensitivity measures of the MCF 10A breast cell line to 8 small molecule perturbagens. Dataset 9 of 15: End-point dose-response metrics for biological replicate 3. | Analysis |
20318 | LINCS MCF 10A Common Project: Rolling-time-point sensitivity measures of the MCF 10A breast cell line to 8 small molecule perturbagens. Dataset 10 of 15: Time-dependent mean normalized growth rate inhibition values for biological replicate 1. | Microscopy/Imaging |
20319 | LINCS MCF 10A Common Project: Rolling-time-point sensitivity measures of the MCF 10A breast cell line to 8 small molecule perturbagens. Dataset 11 of 15: Time-dependent mean normalized growth rate inhibition values for biological replicate 2. | Microscopy/Imaging |
20320 | LINCS MCF 10A Common Project: Rolling-time-point sensitivity measures of the MCF 10A breast cell line to 8 small molecule perturbagens. Dataset 12 of 15: Time-dependent mean normalized growth rate inhibition values for biological replicate 3. | Microscopy/Imaging |
20321 | LINCS MCF 10A Common Project: Rolling-time-point sensitivity measures of the MCF 10A breast cell line to 8 small molecule perturbagens. Dataset 13 of 15: Time-dependent dose-response metrics for biological replicate 1. | Analysis |
20322 | LINCS MCF 10A Common Project: Rolling-time-point sensitivity measures of the MCF 10A breast cell line to 8 small molecule perturbagens. Dataset 14 of 15: Time-dependent dose-response metrics for biological replicate 2. | Analysis |
20323 | LINCS MCF 10A Common Project: Rolling-time-point sensitivity measures of the MCF 10A breast cell line to 8 small molecule perturbagens. Dataset 15 of 15: Time-dependent dose-response metrics for biological replicate 3. | Analysis |
Batch Information:
HMS LINCS Batch ID | Provider | Provider Catalog ID | Provider Batch ID |
---|---|---|---|
51124-1 | Mario Niepel (Harvard Medical School) |